Wellcome

Bone response to dental implant materials / (Record no. 504257)

MARC details
000 -LEADER
fixed length control field 04913cam a2200553Ii 4500
001 -
control field ocn961910097
003 -
control field OCoLC
005 -
control field 20190719103349.0
006 -
fixed length control field m o d
007 -
fixed length control field cr cnu|||unuuu
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161102t20162017enk o 001 0 eng d
040 ## -
-- N$T
-- eng
-- rda
-- pn
-- N$T
-- IDEBK
-- EBLCP
-- OPELS
-- YDX
-- N$T
-- OCLCQ
-- OTZ
-- OCLCQ
-- U3W
-- D6H
-- UKMGB
-- CNCGM
015 ## -
National bibliography number GBB6J3298
Source bnb
016 7# -
Record control number 018090123
Source Uk
019 ## -
-- 961934554
-- 967719053
-- 972778064
-- 972953219
-- 973056505
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9780081002889
Qualifying information (electronic bk.)
International Standard Book Number 0081002882
Qualifying information (electronic bk.)
-- 9780081002872
Qualifying information (print)
-- 0081002874
035 ## -
-- (OCoLC)961910097
-- (OCoLC)961934554
-- (OCoLC)967719053
-- (OCoLC)972778064
-- (OCoLC)972953219
-- (OCoLC)973056505
050 #4 - LIBRARY OF CONGRESS CALL NUMBER
-- RK667.I45
060 #4 -
-- WU 640
072 #7 -
-- MED
-- 001680
-- bisacsh
082 04 -
Classification number 617.6/93
-- 23
245 00 - TITLE STATEMENT
Title Bone response to dental implant materials /
Statement of responsibility, etc edited by Adriano Piattelli.
300 ## - PHYSICAL DESCRIPTION
Extent 1 online resource.
505 0# -
Formatted contents note Front Cover; Bone Response to Dental Implant Materials; Related titles; Bone Response to Dental Implant Materials; Copyright; Contents; List of contributors; 1 -- Introduction to bone response to dental implant materials; 1.1 Introduction; 1.1.1 Bone structure in the aspect of functionality; 1.1.2 Bone remodeling; 1.1.3 The modern concept of biocompatibility; 1.2 Biomaterials; 1.2.1 Autologous bone; 1.2.2 Porous phycogenic hydroxyapatite; 1.2.3 Collagenized porcine biomaterial; 1.2.4 Anorganic bovine bone; 1.2.5 Biphasic calcium phosphate; 1.2.6 Calcium carbonate
Formatted contents note 1.3 Challenges and further trends1.3.1 Graphene; 1.3.2 Biomedical applications; Acknowledgment; References; 2 -- Mechanical modification of dental implants to control bone retention; 2.1 Introduction; 2.2 The implant as extracellular matrix; 2.3 Cell attachment; 2.4 Cell behavior on smooth surfaces; 2.5 Cell behavior on three-dimensional and roughened surfaces; 2.6 Mechanisms involved with translation of cell configuration to differentiation; 2.7 Using controlled surface configuration to control cell function-tissue engineering surfaces
Formatted contents note 2.8 Mechanical basis for bone retention around dental implants2.9 Conclusion; References; 3 -- Surface modification of dental biomaterials for controlling bone response; 3.1 Bone responses to implant surfaces; 3.2 Roughening the surface; 3.2.1 Surface characteristics; 3.2.2 The effect of surface topography on bone healing; 3.3 Application of inorganic elements to implant surfaces; 3.3.1 Calcium phosphorus; 3.3.2 Fluoride treatment; 3.4 Application of organic compounds to implant surfaces; 3.5 Concluding remarks; References; 4 -- Bone response to calcium phosphate coatings for dental implants
Formatted contents note 4.1 Introduction4.2 The bone implant interface; 4.3 Methods of calcium phosphate coating; 4.3.1 Plasma sprayed coatings; 4.3.2 Thermal spray coating technique; 4.3.3 Solgel coating; 4.3.4 Sputter deposition; 4.3.5 Pulsed laser deposition; 4.3.6 Dip-coating technique; 4.3.7 Ion beam assisted deposition of CaP; 4.3.8 Electrophoretic deposition; 4.3.9 Hot isostatic pressing technique; 4.3.10 Biomimetic precipitation; 4.4 Surface coating and peri-implant wound healing process; 4.5 Factors influencing the coated implant bone interface; 4.5.1 Surface morphology/surface topography
Formatted contents note 4.5.2 The chemical composition and CaP ratio4.5.3 Phase composition and structure; 4.5.4 Coating dissolution of HA; 4.6 CaP coating as drug delivery system; 4.6.1 Silicon; 4.6.2 Strontium; 4.6.3 Silver; 4.6.4 Bisphosphonate; 4.6.5 Proteins; 4.7 CaP coating and peri-implantitis; 4.8 Conclusion; References; 5 -- Peri-implant biological behavior: clinical and scientific aspects; 5.1 Introduction; 5.2 Implant features; 5.2.1 Surface; 5.3 Implant anatomy; 5.3.1 Implant neck design; 5.3.2 Middle threads configuration; 5.3.3 Apex; 5.4 BIC percentage; References
Formatted contents note 6 -- Implant primary stability and occlusion
500 ## - GENERAL NOTE
General note Includes index.
650 #0 -
Topical term or geographic name as entry element Dental implants
Topical term or geographic name as entry element MEDICAL / Dentistry / Dental Implants
Topical term or geographic name as entry element Dental Implants
700 1# -
Personal name Piattelli, Adriano,
Relator term editor.
856 40 -
Uniform Resource Identifier http://www.sciencedirect.com/science/book/9780081002872
264 #1 -
-- Duxford, United Kingdom :
-- Woodhead Publishing is an imprint of Elsevier,
-- [2016].
-- �2017
336 ## -
-- text
-- txt
-- rdacontent
337 ## -
-- computer
-- c
-- rdamedia
338 ## -
-- online resource
-- cr
-- rdacarrier
490 1# -
-- Woodhead Publishing series in biomaterials.
588 0# -
-- Online resource; title from PDF title page (ScienceDirect, viewed November 14, 2016).
650 #0 -
-- Materials
-- Biocompatibility.
-- bisacsh
-- adverse effects.
655 #4 -
-- Electronic books.
776 08 -
-- Original
-- 0081002874
-- 9780081002872
-- (OCoLC)952647023
830 #0 -
-- Woodhead Publishing series in biomaterials.
856 40 -
-- ScienceDirect
Holdings
Withdrawn status Lost status Damaged status Home library Current library Date acquired Total Checkouts Barcode Date last seen Koha item type
      Mysore University Main Library Mysore University Main Library 19/07/2019   EBKELV558 19/07/2019 Ebooks

No. of hits (from 9th Mar 12) :